Sekonic FLASHMATE L-308BII Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Pomiary, testowanie i kontrola Sekonic FLASHMATE L-308BII. Sekonic FLASHMATE L-308BII Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Operating Instructions

EXPOSURE METEROperating Instructions

Strona 2 - SAFETY PRECAUTIONS

6. Ambient Light Measurement6.1 Mode Selection0 Press the mode selector to enter the ambient lightmeasurement mode.0 Set up the film and shutter speed

Strona 3 - CONTENTS

7.. Flash Measurement with cord7.1 Setting up of the flash measurement with cord and makingmeasurement in this mode0 Press the mode selector to enter

Strona 4 - 1. Parts Designations

8. Flash Light Wireless Measurement(Measurement without using the syrchro cord)8.1 Flash light wireless measurement(1> Press the mode selector to e

Strona 5 - 2. Display

ow to use the Lumidisc9.1 How to measure light contrast@) Fit the Lumidisc on the light receiving part.See page 3 ‘3.2 How to fit the Lumidisc’.@ Sel

Strona 6 - 3. Mode Selection

10. SpecificationsType l Digital exposure meter for ambient and flash meteringLight-receiving methodl Incident and reflected light meteri

Strona 7 - Light-receiving Method

11. Instructions and Maintenance NotesCaution: l To avoid damaging your L-308611, never drop it or subject it to impact.0 Avoid keeping your L-30

Strona 8 - 5.3 Auto Power-off

Quick Guide to the Sekonic L-308ON/OFFBATTERY CHECKMEASUREUPDOWN1/10 STOPINCREMENTSISO· DEPRESS WHILE PUSHING UP ORDOWN SWITCH· IN DAYLIGHT MODE , TO

Strona 9

Basic Operation - Sekonic L-308On/Off/Battery CheckPress Power button. To check battery power hold downbutton. Power is indicated in 1/10th stepsSet I

Strona 11 - Flash Measurement with cord

SAFETY PRECAUTIONSThis manual uses the following safety labels for WARNING and CAUTIONthat you must follow.Indicates hazards or unsafe practices tha

Strona 12

q Operating instructionsSAFETY PRECAUTIONSThis manual uses the following safety labels for AWARNING and ACAUTIONthat you must follow./b WARNING Indi

Strona 13 - How to measure light contrast

Table of ContentsSafety PrecautionsTable of Contents1. Parts Designation ...12.

Strona 14 - Specifications

1. Parts DesignationStrapPower Button(ON/OFF Switch)Lumisphere Lumisphere Mode ButtonMeasuring ButtonLiquid Crystal Display (LCD)Up ButtonDown Butto

Strona 15

2. Explanation of the Liquid Crystal Display (LCD)*For explanation purposes, the display illustrated here shows icons andreadouts simultaneously. Ac

Strona 16

3. Before UsingWARNING1. Attach the strap1) Attach the Strap !5 by passing the small endloop through the strap eyelet !2 and passing theother end of

Strona 17 - PRINTED IN USA

3. Before Using3. Checking battery capacityWhen the Power button q is ON, the battery power indicator on the LCD t isdisplayed.(Displayed) Battery

Strona 18 - FLASHMATE

3. Before Using5. Auto Power OFF function1) To conserve battery power, the meter will turn OFF about four minutes afterlast use.2) Whether the Auto

Strona 19 - ■ SAFETY PRECAUTIONS

4. Basic Operation1. Incident or reflected light measuring1) To set for either incident or reflected light operation, slide the Lumisphere wmounting

Strona 20 - Table of Contents

4. Basic Operation2) Interchangeably switch between EV modeand Shutter Speed Priority mode by pressingthe Mode button e while holding down theISO b

Strona 21 - 1. Parts Designation

4. Basic Operation3. When set for incident lightIncident light measuring is the measurementmethod that employs either the Lumisphere orLumidisc func

Strona 22

4. Basic Operation4. When set for reflected lightPoint the lens of the exposure meter toward thepart of the subject to be measured from thecamera posi

Strona 23 - 3. Before Using

CONTENTSSAFETY PRECAUTIONS ... iCONTENTS ...

Strona 24

5. Measurement1. Measuring Ambient LightIn this measurement mode, we have the choiceof shutter priority mode and EV mode. Press theMode button e to

Strona 25

5. Measurement✩ When the display range is exceeded, and E.o appears, press the Up button yto change the shutter speed to the high-speed side and thu

Strona 26 - 4. Basic Operation

5. Measurement2) Press measuring button r to make ameasurement. Release the measuring button tocomplete the measurement. The measured value(EV value

Strona 27

5. Measurement1-3 Cinematography1) Press Mode button e to selectShutter Speed Priority mode.2) Press the Up button y or Downbutton u to select the c

Strona 28 - Section B

5. Measurement2. Measuring Flash LightThis measuring method comprises the cord and cordless flash modes. Measurethe flash light to display shutter s

Strona 29 - 4. Basic Operation

5. MeasurementNOTE: ● There is a danger of electric shock if the meter is handled withwet hands, during rain, in areas splashed by water or wherethe

Strona 30 - 5. Measurement

5. Measurement✩ When the display range is exceeded (E.u), press the Down button u tochange the shutter speed to the low-speed side, or raise the qua

Strona 31

5. Measurement4) If the 90 second period is exceeded and theblinking mark stops, press the Measuringbutton again to return to ready to measure.5) Wh

Strona 32 - Measurement value (EV)

6. Advanced Functions1. Measuring Light ContrastThis method is used to check studio lighting or lighting unevenness.1) Mount the Lumidisc accessory

Strona 33

6. Advanced Functions2. How to use an incident illuminance (LUX or FC) meter1) Mount the Lumidisc accessory (see page 8).2) Set EV mode and ISO 100.

Strona 34

1. Parts DesignationsPower button/Lumisphere(Light receiving element) Lens (Light receiving element)\Up/Down buttonIS0 buttonSynchro termin

Strona 35

3. Custom setting functionTo match your camera, you can set the setting valueand display value to full, 1/2 or 1/3 stop.1) To enter custom setting mod

Strona 36

7. Accessories● Synchro cord (Sold Separately)This is a five-meter long cord withthree plugs. An exposure meter, acamera, and a flash can all beconn

Strona 37 - Set shutter speed

8. Technical DataType • Digital exposure meter for ambient and flash lightLight receiving method • Incident light and reflected lightLight receiving

Strona 38 - 6. Advanced Functions

NOTE: ● To avoid damage to meter, never drop or subject it to shock.● Avoid storping meter in places with high temperature and/orhumidity.● Be careful

Strona 39

7-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU, TOKYO 178-8686, JAPANTEL: +81(0)3-3978-2335 FAX: +81(0)3-3978-5229http://www.sekonic.co.jp/EnglishJE109756

Strona 41 - 7. Accessories

2. Display2.1 LCD panel0 Mode selectionAmbient light measurementFlash measurement without cordFlash measurement with cord0m IS0 film speed display. S

Strona 42 - 8. Technical Data

3. Mode SelectionYour L-308Bll can measure both incident and reflected light in both ambient light and flash light(electronic flash or flash bulb) mod

Strona 43 - Maintenance Notes

4, Light-receiving Method4.1 Incident light meteringHold L-308BII close to the subject, point the lumisphere towards the camera, and measure theincide

Strona 44 - JE1097560-00

5. Preparation for Measurement5.1 Inserting the batteryUse a 1.5-volt, type-AA battery.Use a manganese dry cell (R6P) or an alkaline one (LR6).Neve

Strona 45

NOTE0 If you press the mode selector in the ambient light measurement mode whileholding down the IS0 button, the display is toggled between EV and F

Komentarze do niniejszej Instrukcji

Brak uwag